Solar Load Controller

HACS Default Release Tests Buy me a coffee

Solar Load Controller icon

Runs a switchable load when solar energy is actually useful - and still guarantees it runs long enough on days when it is not.

It combines live grid import and export, a PV forecast, optional battery data and a daily runtime target into one decision, re-evaluated every minute. No YAML, no hardcoded values, no assumptions about your hardware.

Is this for you?

You will get something out of this if:

  • Your PV array is larger than your inverter can output - a 1.8 kWp setup behind an 800 W limit, for example.
  • You have a load worth scheduling: a pool pump, a water heater, a dehumidifier, a car charger, anything behind a switch or input_boolean.
  • That load needs a minimum runtime per day whether the sun cooperates or not.
  • A simple "run when export > X" automation keeps switching it on and off, or pulls from the grid when the household is already using the inverter output.

If your inverter can always cover both the house and the load, a basic threshold automation will do and you do not need this.

The problem it solves

On a strong day the battery fills up and the inverter can no longer use the full available solar power - energy is clipped and wasted. On a weak day the load still has to run, and forcing it at the wrong moment means buying electricity you did not need to.

In between sits the hard part: when the stove is on, the limited inverter output is already spoken for, and starting a pool pump means importing from the grid. A threshold automation cannot tell the difference, so it oscillates.

Solar Load Controller makes that call automatically:

  • Weak forecast days - stays defensive early, waits while the forecast and the remaining time still justify it, and forces runtime only when the deadline demands it.
  • Strong forecast days - uses surplus before it is clipped, then becomes stricter once the daily target is met so the battery can still finish charging.
  • House loads take priority - when the household consumes the available inverter output, the controlled load stops.
  • Spikes are filtered - a two-second smart meter or inverter reaction does not switch anything.
  • Manual control always wins - pause the automation and operate the load by hand.

Two days of decisions, pump state and PV output

Two days in August. Top row the decision reason, below it the pump, underneath the PV output. The runs sit on the solar peak instead of next to it, in a few long blocks rather than a dozen short ones.

Installation

Solar Load Controller is in the HACS default store - no custom repository needed.

Open in HACS

  1. Open HACS, search for Solar Load Controller, install it.
  2. Restart Home Assistant.
  3. Add it under Settings → Devices & services → Add integration.

Setup runs entirely through the config flow - six steps, no YAML, in English or German.

First step of the config flow

What you need

Required

Input Notes
Load switch a switch or input_boolean entity
Load power in watts
Runtime window earliest start, latest finish, minimum daily runtime
Minimum on / off time protects the appliance from short cycling
Grid import and export sensors positive watt values
PV array size in kWp
PV forecast for today in kWh
High day threshold in kWh/kWp

Optional, but the controller gets noticeably better with them

Input What it enables
Current PV power present-tense checks instead of forecast-only decisions
Inverter AC limit recognising clipped power that cannot serve an AC load
Forecast next hour / remaining today waiting for a better window
Battery SoC, power, sign, capacity, mode battery-aware priority and surplus
Debug sensor and decision log full traceability of every decision

PV forecast

Developed and tested against BJReplay/ha-solcast-solar.

Any forecast integration works if it provides stable numeric sensors for forecast today in kWh, next hour, and remaining today.

How it decides

Mode decision matrix

The day is classified once each morning after 06:00 from the forecast, in kWh/kWp, into one of three classes. A manual override select (auto, low, mid, high) is available for testing.

High mode

For strong forecast days. Prefers direct solar and export-aware runtime decisions, then becomes stricter after the minimum runtime is met so remaining forecast can still cover battery charging, household reserve and the late-day battery-priority buffer.

The daily runtime target is a floor, not a cap: on a strong day the load deliberately keeps running on surplus that would otherwise be exported or clipped.

Mid mode

The calm middle band. It can wait for a clearly better next-hour window, allow a simple assisted start, and otherwise falls through to the shared completion logic without low-mode pressure or hold hysteresis. Assisted starts use AC-usable current solar, including solar routed into battery charging, but never active battery discharge.

Low mode

For weak days. Stays defensive early, prefers waiting while forecast and remaining slack still justify it, and becomes progressively more willing to assist or force runtime later in the day. Separate helpers handle runtime pressure, forecast-aware waiting, assisted starts on partial solar, and deadline-driven forcing.

For the decision tree, helper functions and tuning constants behind each mode, see docs/decision-model.md.

Entities

Entity IDs include the configured integration name. Display names follow your Home Assistant language - shown here in German; technical state values stay English so automations built on them do not break.

Controls and sensors in Home Assistant

One strong day: four automatic starts, 188 minutes of runtime of which 183 came from solar, and nothing forced from the grid.

Entity Purpose
switch.<name>_automation_paused hand control back to yourself
select.<name>_forecast_day_mode_override force a day class for testing
sensor.<name>_decision_reason why the load is on or off right now
sensor.<name>_runtime_today runtime so far
sensor.<name>_runtime_remaining_today still to go against the target
sensor.<name>_solar_runtime_today of which was covered by solar
sensor.<name>_forced_runtime_today of which had to be forced
sensor.<name>_energy_today estimated consumption
sensor.<name>_switch_cycles_today automatic starts today
sensor.<name>_available_surplus grid-free surplus
sensor.<name>_effective_solar_surplus including AC-usable battery charge
sensor.<name>_forecast_day_mode today's class
sensor.<name>_decision_debug full decision trace, when debug is enabled

Decision states

sensor.<name>_decision_reason reports one of:

solar · export_guard · forecast_run · forecast · low_assist · low_wait · grid_import · battery · battery_priority · runtime_force · runtime_met · paused · waiting · missing_sensor · min_on · min_off · time_window

Debug log

With debug enabled, every decision change is written to:

/config/solar_load_controller_decisions.jsonl

One JSON object per line, starting with the local timestamp, containing the final decision, every decision input, the relevant settings and the raw Home Assistant states of the configured entities. That is enough to reconstruct any switching behaviour after the fact.

The file is a rolling window of the most recent 2000 decisions: once full, the oldest line is dropped as a new one is written, so the size stays bounded and recent history is always present. The path is also exposed on the debug sensor as debug_log.path.

Support

Report bugs, unexpected switching or setup problems here:

GitHub Issues

With debug enabled, include the relevant lines from /config/solar_load_controller_decisions.jsonl - they usually contain the whole answer.

Anonymous usage statistics

Once a day the integration sends a randomly generated installation ID and its version number, so active installations can be counted - the HACS download counter cannot distinguish an install from an update or a removal. Nothing else is transmitted: no host names, entities, devices, measurements, locations or settings.

Switch it off under Settings → Devices & Services → Solar Load Controller → Configure → Advanced. The integration behaves identically either way.

The collector that receives it is in backend_server/, and the resulting numbers are public: https://telemetry.cloudpichler.net

Development

python3 -m venv .venv
.venv/bin/python -m pip install -r requirements-dev.txt
.venv/bin/python -m pytest tests

Syntax and translation checks:

python3 -m py_compile custom_components/solar_load_controller/*.py
python3 -m json.tool custom_components/solar_load_controller/translations/de.json
python3 -m json.tool custom_components/solar_load_controller/translations/en.json