Local-first temperature monitoring for up to five DS18B20 probes on one shared 1-Wire bus, a read-only 1.8-inch ST7735 LCD (an optional 240 × 320 ST7789 build exists), and a self-hosted React web application.
Firmware implements sensor discovery, calibrated readings, status/alerts,
ROM-keyed settings, five-minute LittleFS history, a protected setup SoftAP,
public read-only HTTP/WebSocket APIs with owner-only changes, and guarded OTA upload/rollback policy.
The React UI includes live dashboard, historical trends/CSV, alerts, sensor
configuration, network/device settings, and firmware/system actions. Native
host tests, simulated network tests, headless LVGL tests and pinned ESP-IDF
v6.1 firmware builds run in CI; selected USB-loopback bare-board checks have
also been recorded separately in docs/validation/.
The LCD runtime includes ST7735/ST7789 SPI and LVGL integration, but physical panel orientation, color, backlight voltage and refresh timing are not qualified. GPIO15 backlight drive must remain disconnected/disabled until the panel's electrical behavior is confirmed. Physical DS18B20 probes, five-probe soak, owner-network onboarding, OTA slot transitions, LittleFS power-loss recovery and destructive reset acceptance remain open. Simulations do not close those gates. No cloud service is required for local sensor acquisition.
- Requirements
- Implementation checklist
- Development and verification
- Progress and limitations
- Wiring and hardware hold points
Start with ./tools/verify.sh. Firmware builds require the pinned ESP-IDF
v6.1 environment; see the development guide for setup, flashing and simulation.
The web app served by the board, and the board's 1.8-inch LCD, on 2026-11-18.
Dashboard: live readings from each probe, a status summary (here, Sensor 4 is disconnected), the active alerts, and the last 24 hours of temperatures.
History: the five-minute temperature history for a chosen range (1 hour to 30 days), with missing intervals shaded and each probe's low, average, high and reading count.
LCD overview: the time, Wi-Fi status and each probe's reading in °F and °C. Sensor 4 is marked LOST (disconnected), and the fifth slot is unused.
LCD trends: the last hour of each probe's temperature in °F. With the display mode set to Extended (Settings), the LCD alternates between the overview and this screen.