Heat pump: COP that follows the outside temperature, and a learned COP (#1081) - #1366

Merged
traktore-org merged 6 commits into
developfrom
feature/1081-cost-of-heat
Nov 14, 2026
Merged

traktore-org merged 6 commits into
developfrom
feature/1081-cost-of-heat

Conversation

@traktore-org

Copy link
Copy Markdown
Owner
  • A heat pump can get a COP curve of 2–3 points (outside °C → COP). The cost of heat uses the COP now; the plan and tomorrow's preview put the heat pump in the hours where heat is cheapest (rank only — kWh and cost stay electricity).

  • The crawler finds a heat meter; SEM learns COP per outside temperature from it. Used only when you pick "learned" for the heat pump.

  • Without a curve or that choice, nothing changes.

  • Simulated winter: learned 2.43 / 3.18 / 3.82 against true 2.43 / 3.20 / 3.83 at −7 / 2 / 12 °C

  • Full suite green, replay unchanged

  • Review, CI, live run on the test server

https://claude.ai/code/session_01UikL7PL23jjzZtjyqe4P8w

…lan ranks its hours by the price of heat

A curve of 2-3 points (outdoor °C : COP) is a per-device goal
(update_device_config property cop_curve). With it, the cost-of-heat
sensor uses the COP at the outdoor reading now (attributes cop_used,
cop_source, outdoor_c) and the night plan ranks the heat pump's grid
slots by price / COP. Rank only: kWh and cost stay electricity. The
plan's why says cheapest_heat with the mean COP. No curve = no change.

Classic load card: COP row and three-point editor under More.

Claude-Session: https://claude.ai/code/session_01UikL7PL23jjzZtjyqe4P8w
The crawler finds the heat meter (a kWh total of heat delivered). Each hour
gives heat / electricity at that hour's outdoor temperature; 2 °C bands,
median, trusted after 6 hours. Standby, short runs, resets and unread or
estimated hours are left out. Nothing acts until the user sets the COP
source to "learned"; outside the learned range the user's curve answers.
Tomorrow's preview now ranks by the price of heat too. The option surface
grows by the heat meter field (#1081, declared in the .loosen file).

Claude-Session: https://claude.ai/code/session_01UikL7PL23jjzZtjyqe4P8w
…ken thermometer

Review findings: hour ids are whole hours since the epoch (no DST double
hour); a gap drops the hour before it; another meter starts fresh; outdoor
readings outside -40..50 °C are no reading; hours under 0.3 kWh are standby
(the ledger rounds to 0.01 kWh). The role leaves out yesterday/last/session
counters and solar, boiler or biomass heat. The plan's COP helper is a
module function, so plan fakes need nothing new. Tests use AST contracts.

Claude-Session: https://claude.ai/code/session_01UikL7PL23jjzZtjyqe4P8w
A meter at COP ~1 is named and learns nothing; a counter too coarse
for an hour, and the hour after a stalled one, are dropped; a bad
store starts fresh; the dead hot-water flag is gone.

Claude-Session: https://claude.ai/code/session_01UikL7PL23jjzZtjyqe4P8w
A stall is caught before the short-run check and ends at a gap; a
counter reset learns the meter's step again; a meter just under COP 1
is named as electric.

Claude-Session: https://claude.ai/code/session_01UikL7PL23jjzZtjyqe4P8w